Notifier FSP-951A-IV Addressable Smoke Detector
Notifier FSP-951A-IV Addressable Smoke Detector
  • Load image into Gallery viewer, Notifier FSP-951A-IV Addressable Smoke Detector
  • Load image into Gallery viewer, Notifier FSP-951A-IV Addressable Smoke Detector

Notifier FSP-951A-IV Addressable Smoke Detector

Regular price
$425.00 CAD
Sale price
$425.00 CAD
Regular price
Sold out
Unit price
per 
Shipping calculated at checkout.

Ivory, low-profile intelligent photoelectric sensor, CLIP and FlashScan, ULC Listed.

NOTE: The -IV suffix indicates this device is compatible with older CLIP communication protocol panels, and is an off-white Ivory color.

The NOTIFIER FSP-951 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the FSP-851 Series. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards.
The FSP-951 Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector’s address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. 

Features
SLC LOOP:
• Two-wire SLC loop connection
• Unit uses base for wiring
• Compatible with FlashScan® and CLIP protocol systems
• Stable communication technique with noise immunity
ADDRESSING:
• Addressable by device
• Rotary, decimal addressing
ARCHITECTURE:
• Sleek, low-profile, stylish design
• Unique single-source design to respond quickly and dependably to a broad range of fires
• Integral communications and built-in device-type identification
• Built-in tamper resistant feature
• Remote test feature from the panel
• Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1(FlashScan systems only)
• Built-in functional test switch activated by external magnet
• Removable cover and insect-resistant screen for simple field cleaning
OPERATION:
• Designed to meet UL 268 7th Edition
• Factory preset at 1.5% nominal sensitivity for panel alarm threshold level
• LED “blinks” when the unit is polled (communicating with the fire panel) and latches in alarm.